Cyber 2.0 OT Protection for OT & IoT Environments

GOALKEEPER

The Goalkeeper of Cybersecurity

Even the best defenses need a way to stop an attack from spreading after it leaves the first computer and enters the network

  1. 1

    Even the world’s best soccer team never takes the field without a goalkeeper

  2. 2

    The goalkeeper does not replace defenders, or stop the striker from shooting. He keeps the ball out of the goal

  3. 3

    Every ball the goalkeeper stops has passed all the defenders

OT PROTECTION BENEFITS

What We Do

Blocks unauthorized software and PCs from reaching controllers and cameras, even after a management PC breach

01

Protects controllers without installing on them

02

No malware detection needed

03

Authorized traffic only (authorized PC + authorized app)

04

Reduces operational risk

05

Protects OT & IoT environments

06

Protects controllers from unauthorized tools, even after a management PC breach

OT

Blocks unauthorized controller access, even in air-gapped networks, without installing software on controllers

IoT

Blocks unauthorized access to protected devices: cameras, sensors, building controls and more

OT DETECTION CHALLENGE

Blocks New Malware Without Needing to Identify It

!OT Detection Challenges in the AI Era
Solution
01
Many industrial networks are offline, preventing regular security updates
01
Works in air-gapped networks without regular updates
02
Disconnection does not guarantee protection: updates, suppliers and equipment can bring threats into isolated networks
02
Maps applications authorized to access controllers (typically just 1–5 applications)
03
New threats may go undetected and greatly increase operational risk
03
Applications outside the Trust List cannot communicate with protected controllers

Controllers Need More Than Detection

OT PREVENTION CHALLENGE

Access Control Without Controller Agents

!OT Prevention Challenges in the AI Era
Solution
01
Installing agents on many controllers is difficult or impossible, and may disrupt their operation
01
External protection, no controller installation
Controller⟵Vortex Gateway⟵Management Server
02
Monitoring and detection may not prevent controller access
02
Access requires an authorized computer and application
Authorized app+Authorized PC
03
A breached management PC also puts the controller at risk
03
Unauthorized apps cannot reach a protected controller, even if the management PC is breached
MONTHLY REPORT

Monthly Proof of Prevention

01

Live Blocking

Lists new and unknown software whose network traffic was blocked, including the reason for each block

02

Retrospective Verification

Lists software whose traffic was blocked in real time and was only later identified as malicious

03

Risk Insights

Threat analysis, exposures and targeted risk reduction advice

When software whose traffic was blocked is later identified as malicious, that is proof it was stopped before it was ever detected

VALIDATION

Test Results: National Energy, Control & Cyber Lab

Cyber 2.0 OT Without protection

In the first test, with protection off, the attack shut down the turbines

Cyber 2.0 OT With protection

In the second test, with protection on, the attack failed and the facility kept operating

Laboratory quotation

“The Cyber2 system has proven its ability to protect PLC controllers in critical manufacturing environment when the system is in defense mode and performs communication port scrambling on network devices”

CHAOS MODEL

The Technology: Mathematical Chaos

Detection-based systems

  • Think in biological terms
  • Hence the terminology: viruses, antivirus, mutations and more
  • They are vulnerable to hackers who use similar models

New malware can outpace detection-based defenses

Based on chaos mathematics

  • Communication channels between protected computers change continuously. Like the weather, they cannot be predicted without the key
  • 7 patents granted

Does not need to identify the threat before blocking its traffic

Authorized softwareThe source computer scrambles the outgoing port
Unauthorized softwareThe outgoing port remains unscrambled
Inside Vortex, before the controller,traffic is descrambled
ABUSE OF LEGITIMATE SOFTWARE

Malware and remote-access tools cannot bypass protection through legitimate software

  1. Malicious SoftwareCommand
  2. PowerShellCommand
  3. HMICommand
  4. Out to Network

Other security systems

Malware can launch a chain of legitimate applications that ends in a seemingly legitimate command.

Other security systems may fail to block that malicious command from reaching OT and IoT devices

Cyber 2.0 Reverse Tracking

Traces the chain, finds unauthorized software at its start, and blocks the communication before it reaches OT and IoT devices

REVERSE TRACKING

Reverse Tracking: Execution Chain Analysis

  1. ⚙Process 1
  2. ⚙Process 2
  3. ⚙Process 3
  4. ⚙Process 4
  5. ⇱Out to Network
  • Records processes and libraries loaded along the chain
  • Records hash values, including MD5 and SHA
  • Records process access and relationships for context analysis
VORTEX

Vortex Gateway: Protection for OT Environments

Integrates into the customer’s SCADA network
Connects transparently to controllers and devices
Controlled deployment to meet facility requirements
Vortex Gateway
NETWORK VISIBILITY

Communication and Blocking Events

Asset connections

Maps links between stations and systems

Investigation

Event source and destination details

Bubble Alerts
Inside the Bubble Alerts view
TRUE PREVENTION

— An Added Layer of Prevention

Phase 01

Asset Visibility

Maps assets, computers and controllers

Phase 02

Detection

Detects anomalies and suspicious behavior

Phase 03

Protocol Inspection

Inspects protocol traffic and commands

New Phase

Access Prevention

Blocks unauthorized traffic to a protected asset

Put a goalkeeper in your network

A short POC, no disruption to your work — and a findings report on everything that was blocked.

Contact Us